Simulation Nodes
Nodes are added and removed automatically, although an updated list requires reloading (right-click on the web interface and choose "Reload") this page.
Most of the entires are self-explaining, and therefore only some fields are explained:
RF Version
All nodes must share the same RealFlow version.
Status
There is a total of seven messages:
Ready | The node is available for simulation. |
---|---|
Disconnected | There is no connection with the manager. |
Ignored | Ignored nodes are those with the “Ignore” flag set to “On” (see Icons > Edit Node below) |
Waiting | The node is currently connected to the manager. If a node stalls on this status for some reason, it can be reconnected with the “retry” action. |
Simulating | A simulation is in progress. |
Unlicensed | The node cannot be used due lacking a valid license. The “retry” action will appear in this case for a second chance. |
Disabled | This can happen when the workgroup it belongs to is disabled or has reached its maximum amount of jobs. |
Icons
Edit Node
Here it is possible to configure a job node.
Name
Enter a node’s real name or IP address as it appears in your network. Blanks or special characters are not allowed.
Ignore
Kick out a job node from the node's list temporarily – even during a running simulation.
Visible
Disconnected nodes will be removed from the node list automatically, but you can force them to be kept by activating this checkbox.
Disable
This option completely disables a node’s functionality.
Reset
Restores the previous settings.
Submit
Passes your settings to the manager. You will probably have to press "Reload" (right-click and choose "Reload") in the web-interface to make the changes visible.
Remove node
Removes the edited node from the "Nodes" table.