RLM is widely spread and many applications use it for licensing:

  • It is only necessary to install one instance of RLM on your entire network and not on each of the computers that will run RealFlow | Cinema 4D. 
  • Another method is to install a new RLM using a different port (see below). This method is recommended when the existing RLM is very old or if you want to keep your licenses separated.
  • To check if there is a RLM server running on your machine, open a browser and enter the following address: localhost:5054

Using An Existing RLM

In this case, please look for the installation directory of the already installed RLM. Then, the license file and the “nextlimit.set” file must be copied to the RLM's directory. Restart.

The “nextlimit.set” file can be found in RealFlow's application folder under “rlm”

Binding RealFlow's RLM to Another Port

5053 is the RLM's default port. If you are using a RLM-licensed software already then port 5053 is in use. The solution is to edit your license file, where you will find a line indicating the used port, for example

HOST localhost xxxxxxxxxxx 5053

Change “5053” to something like 5052, or 5060, but do not use 5054, because this port is occupied by the RLM's web interface.