  • Locate the the maxwell_suite_floating.lic file in the computer that's running the RLM License Server and open it in a text editor. For the location of this file, please see the Licensing page.
  • Edit the first line of the license to change the 5053 port to something else, such as 5055. Save and close the .lic file.
  • In case you also have a maxwell_license.lic file in this folder, open and edit the port nr in this file as well.
  • Reboot your computer for the RLM License Server to pick up the changes.
  • Now Maxwell should connect to the server using this new port.
  • You need to open the maxwell_license.lic file on all the computers that are running Maxwell and also edit the port nr in these files.

...