Here you can find everything to start, resume, and control a simulation. The two main buttons, “Simulation” and “Reset”, carry small triangles where you can find additional functions and settings. The “Simulation” button's submenu especially contains very important parameters under the “Options…” menu.
Simulate
With this button you can trigger a simulation. During this process RealFlow performs all of the necessary calculations, generates the data files and writes them to disk. The simulation itself obeys several settings that can either be defined globally with "Preferences" or individually for each scene. For adjusting the settings per scene, simply click on the little small triangle to expand a new menu.
Reset
With this button you remove all previously simulated data. The orange progress bar in the timeline disappears and everything is reset to the currently saved state. If you have accidentally pressed “Reset”, it is possible to restore the cached simulation data with Alt + U.
“Simulation” Context Menu
The small button with a triangle next to “Simulation” contains four entries:
Fluid Dynamics/Object Dynamics
These options switch the appropriate simulation engines off or on. By default, the solvers are activated, but if you disable one of these options you will be asked to confirm your choice.
Command line
RealFlow comes in two flavours: the standard application uses a graphical user interface – a GUI. There you always have visual feedback from simulations and mesh creation, you can adjust the parameters and use the built-in main tools and functions. Another way to open RealFlow is without its GUI. In this case, RealFlow is started from a terminal application, e.g. “bash” or OS X's “Terminal” program. Here, you do not have any control elements and the loaded scene must be completely prepared inside the GUI application and be ready to simulate.
...
You can trigger a simulation directly on RealFlow's “-nogui” version. You do not have to create long terminal strings manually anymore in order to start the process and everything will be done automatically. As long as this option is activated, RealFlow will always send the currently opened project to the terminal. To deactivate this feature, simply click on “Command line” again to remove the tick. For more information about RealFlow's “Command Line” version, please click here.
Command line options...
Please see below for a detailed description of the contained settings and options.
Options...
This part is probably of great interest, because there you will find all simulation-related settings. An in-depth explanation of the different parameters can be found in the "Simulation - Timeline & ScaleOptions" chapters
Command line options...
With the help of this panel it is possible to configure a command line simulation. The parameters do not have any effect on GUI simulations.
"Range" Section
Same as scene
When this option is checked the command line simulation's range is exactly the same as the one adjusted on the timeline. To specify a new range, disable “Same as scene” and enter your values in the unlocked fields below.
Frame begin/Frame end
If you want to perform a simulation within a specified range only, uncheck “Same as scene” and enter start and stop frames. Please make sure that “Frame begin” is smaller than “Frame end” to get a plausible result. “Frame begin” also needs to be adjusted if you want to resume a simulation from a certain point in time.
"Threads" Section
Same as scene
This option is enabled by default and the number of threads is read from the scene's “Simulation options”. In some cases, for example with very low particle counts, it is often helpful to use only one or two threads to accelerate the simulation. If you disable the checkbox the “Threads” field becomes editable.
Threads
To enter a new number of threads you have to disable “Same as scene” first. Then, you can enter a new value.
"Args" Section
None
With this option enabled, RealFlow will perform a “normal” simulation using the current scene's settings; the simulation performs exactly the same way as if you were executing it inside the GUI version – but faster.
Reset
When “Reset” is active, the simulation will be reset before it finally starts. All previously cached data will be overwritten.
Use cache
When this argument is enabled RealFlow will load all available cache files for the start frame (see “Range” field) directly before the simulation starts. This option has to be active if you want to resume from an interrupted simulation. Without "Use cache", the simulation simply starts from the specified frame without reading previously stored data.
Mesh
If you only want to perform the creation of meshes from already cached data please choose this mode. In this case, the “Command Line” version will not simulate again and already existing files will be kept.
“Reset” Context Menu
Next to the “Reset” button, you will find an expansion menu again with “Reset To Initial State”. By activating this option it is possible to read from a previously simulated, and saved, initial state (which can be compared with a preset), and start the simulation using these particular settings.
...